When considering cable length, what is the minimum configurable baud rate for Signatures?
FollowThe real time transfer rate from a Signature instrument is found through the calculation of memory consumption in the Signature Deployment software, and this memory usage is equivalent to the amount of data output in real time for the given configuration. In the Deployment Software you will get information about the minimum configurable baud rate and the maximum RS422 cable distance possible, under the "Summary" tab in the "Effects" view. The limitations are given in the table below.
Maximum configurable baud rate | Maximum cable length (m) | Data transfer rate (kB/s) |
125000 | 90 | 122 |
625000 | 187 | 61 |
460800 | 251 | 45 |
230400 | 490 | 22.5 |
115200 | 976 | 11.25 |
Comments
0 comments
Please sign in to leave a comment.